top of page

ONECERA Implant Systemâ„¢ is packaged in an ISO Class 7 clean room.

This allows the implantologist to transfer the implant freely during the operation without touching the implant.

​

The implant can be easily removed out of the Titanium sleeve in which it is positioned. The cover screw is secured inside the lid that seals the tube for the user’s convenience. Finally, the implant is mountless inside the sleeve. This mountless design allows the implantologist to remove the implant with any insertion instrument he wishes; hand key, ratchet adaptor or motor.

One514-3D
One512-3D
One510-3D
One508-3D
One414-3D
One412-3D
One410-3D
One408-3D
One314-3D
One312-3D
One310-3D
One308-3D
One214-3D
One212-3D
One210-3D
One208-3D
oneq4 png.png

ONECERA IMPLANT

  • A GAP FREE ONE PIECE TITANIUM IMPLANT

  • ATRAUMATIC ONE-PHASE CONCEPT

  • IMMEDIATE TEMPORISATION & IMMEDIATE LOADING POSSIBILITIES

  • EASY TO FOLLOW TREATMENT SEQUENCE

  • CLEARLY ARRANGED TITANIUM INSTRUMENTS

01

Concept

This affordable implant system was created to meet various needs in implant dentistry. Engineered for ease of use and clarity, it overcomes many of the drawbacks associated with older implant systems. Constructed from titanium, this single-phase endosseous implant is free of complex components.

The self-cutting thread provides excellent primary stability, facilitating the immediate placement of a temporary crown. The transgingival healing method eliminates the need for a second surgical procedure, while the sandblasted surface speeds up osseointegration. Additionally, the mirror-finished implant head supports wound healing and minimizes the risk of post-operative infections.

03

The Thread

ONECERA Implants feature a self-cutting thread that enables gentle bone management and atraumatic insertion with minimal force. These implants provide high primary stability even in the spongy bone of the upper jaw. We focused extensively on creating a progressively designed thread with axial milling cuts to minimize stress and strain.

This design ensures that jaw pressure is distributed evenly across the bone and helps prevent rotation. Additionally, bone shavings can be collected and reused during the osteogenesis process.

02

The Implant Head

The implant features a 6° cone design at its top, which allows it to be precisely ground and treated similarly to a natural tooth. To prevent rotation, it includes four symmetrical axial slots. These slots not only guide the wrench for implant insertion but also support the installation of a temporary suprastructure.

Before taking impressions, the slots should be filled with composite material. With the use of a dental dam, the top can be ground during or immediately after surgery. The mirror-finished surface aids in managing mucosa and gum, enabling your patient to leave your office with both an aesthetic and functional solution on the same day as the surgery.

04

The Surface

ONECERA Implants feature a sandblasted, large grit, acid-etched surface (SLA) designed to enhance osseointegration by increasing bone-to-implant contact (BIC). The SLA process combines grit blasting and acid etching to create a rough surface that promotes osteoblast proliferation and adhesion. This leads to improved stability and longevity of the implant. By increasing the surface area, we further enhance osteoblast activity and cellular adhesion, resulting in more effective osseointegration.

ONECERA Implant

  • High Initial Stability

  • Smoother Insertion

  • Simple & Easy Depth Control

  • Improved Joint-Stability

  • S.L.A Surface

  • Strict Cleaning

  • Powerful Drilling

The ONECERA Implant System

• User-friendly design and simplified protocols
• Quick and easy placement and restoration for efficient results
• Affordable pricing for increased access to dental implants
• Committed research and development for improved delivery of care
• Practical education to ensure users confidence and high success rates

Screenshot 2024-08-21 at 8.35.37 PM.png
Screenshot 2024-08-21 at 8.35.44 PM.png

Advantages of ONECERA Fusion Implants

  1. Streamlined Design: A single-piece implant with no joints.

  2. Integrated Structure: The implant and abutment are fused into one piece, eliminating microgaps that can reduce bone loss and prevent odor.

  3. Efficient Procedure: Often performed in a single visit and usually flapless, avoiding open surgical procedures. The process is quicker than traditional bridgework.

  4. Immediate Loading: Crowns or bridges can be placed on the same day as the implant.

  5. Conventional Impressions: Impressions can be taken just like with traditional bridgework, saving time.

  6. Versatile Options: Available in various sizes and designs to fit different bone types and measurements, potentially reducing the need for bone augmentation and sinus lifts.

  7. Cost-Effective: Generally more affordable than two- or three-piece implants.

  8. Efficient Placement of Prosthetics: Crowns and bridges can be cemented in place within a day.

  9. No Abutment Screw Issues: Eliminates problems with abutment screw loosening due to the absence of separate screw-implant assemblies.

  10. Self-Drilling and Stable: Provides strong initial loading with self-drilling capability.

System Specifications

The immediate loading capability of the ONECERA Fusion Implant is attributed to two key factors:

 

the principle of bicortical penetration and the fact that the ONECERA implant is a one-piece monolithic system with an integrated abutment at the top.

​

Bicortical:

Unlike traditional multi-piece implant systems, the ONECERA Fusion Implant is designed to be anchored between both cortical bone sites in the jawbone. This setup offers exceptional primary stability, as the cortical bone can immediately bear a substantial load, unlike the less stable trabecular (cancellous) bone. Since the implant does not require bone healing or initial stability, patients can comfortably chew and apply pressure to the implant site.

​​

Single-Piece Implant System:

As a single-piece system, the ONECERA Fusion Implant has the benefit of being more compact than traditional multi-piece implants. This is because it does not require the wider well needed for abutment placement. By taking up less space, the implant reduces bone loss and therefore shortens the time needed for bone healing.

Surface

화면 캡처 2024-10-31 210816.png

SEM topography of sandblasted Ti implant.

화면 캡처 2024-10-31 210830.png

SEM topography of SLA surface.

Bone Fusion to Implant

화면 캡처 2024-10-31 205521.png
화면 캡처 2024-10-31 2055212.png

Histological image of new bone apposition over the implant surface at four weeks.

화면 캡처 2024-10-31 205549.png
화면 캡처 2024-10-31 2055492.png

 Bone formation along the SLA surface from the cortical bone to the apex.

The ONECERA Implant System is a single-piece implant designed to connect directly to the bone at its apical end, providing exceptional primary stability due to its integration with the cortical (basal) bone.

​

The system’s integrated superstructure allows One-Step Fusion Implants to endure greater forces, eliminating issues such as neck fractures, screw loosening, and screw breakages commonly associated with multi-piece implants.

​

ONECERA IMPLANT SURFACE offers several notable benefits, including:

  • Strong Long-Term Performance: Various studies have demonstrated the consistent reliability of SLA implants over time.

  • Reduced Healing Time: Research indicates that SLA implants can expedite the healing process.

  • Low Prevalence of Peri-implantitis: Evidence suggests that patients with SLA implants experience a low incidence of peri-implantitis.

  • High Survival Rates: Research shows that SLA implants achieve high survival rates, with some studies reporting rates of 95.1% after 10 years.

​

The surface of a dental implant is essential for its durability and bone fusion, as the shape, structure, and surface characteristics all contribute to its stability.

​​

ONE 5.png
ONE 4.png
ONE 3.png
ONE 2.png
bottom of page